How many microinverters can you put on a single-phase installation? And a three-phase installation?
In single-phase, 10 microinverters can be connected. In a three-phase installation, up to 30 microinverters can be connected on a single 20A three phase circuit breaker. Larger systems can be constructed with multiple AC branch circuits.
How is a system fault detected?
All AC module installations must be Internet connected for the monitoring to receive the 25-year microinverter warranty. This Internet connection reports data to the Enphase monitoring platform, Enlighten on a per microinverter/module basis. The performance of each microinverter and module is visible to the installer via Enlighten and alerts are provided for any faulty equipment, such as an under-performing PV module or a faulty microinverter.
Is the AC module compliant with RD 244 for zero injection? Can it be used for isolated installations?
No, export limiting functionality is not yet compliant with RD 244/2019. Most installations with Enphase microinverters are residential scale (below 15kW) and are easily accepted without this compliance.
Each microinverter is a single phase device. Three-phase installations are constructed with single phase microinverters distributed across the phases. The inverter will monitor power consumption at each phase using the CTs connected to the Envoy-S communications gateway, limiting grid export to the defined level, either on a per phase or aggregate basis as required.In three-phase installations, can you divide surpluses by phases?